Overview
Rosahl dehumidifier membranes are typically installed inside an enclosure; however, for small enclosures, external installation is also possible. The MDL-3-SET enables external installation by reversing the moisture outflow to dehumidify the enclosure. When used with the VREG2 USB-C power supply adapter, it offers a convenient, low-power dry storage solution.

Important:
Reversing the polarity of the power to the membrane will permanently damage the membrane. When correctly installed, this installation kit ensures correct operation.
The membrane kits work with a wide range of sealed enclosures and cabinets to protect sensitive equipment from humidity damage and condensation. They also fit applications like Bambu Lab AMS or other 3D printer filament drying systems, turning them into maintenance free electric dehumidifiers without needing desiccants.

Assembly & Mounting Instructions

  1. Mounting Cover Components

The mounting kit includes a three-part mould set (see image).

  • Front frame – holds the membrane and USB-C power module.
  • Retainer frame cover – secures components in place.
  • Backplate – optional for extra support on flexible enclosure walls
  1. Marking and Preparing the Cutout
  2. Use the supplied backplate as a template for installing the mould.
  3. Position the backplate at the desired location and mark screw holes. It may be easier to hold it upside down.
  4. Drill one hole first, temporarily bolt the fixture in place, then drill the remaining holes. Use a 3.5 mm drill bit for mounting holes. The fixture’s holes are slightly oversized to allow for alignment.
  5. Mark and cut out the opening for the membrane using for example:
  • Rotary tool with a cutting disk.
  • Manual method: Drill a rectangle of small holes and file until edges are smooth.

Assembly & Installing Components

 

  1. Installing the Components

Caution: Do not touch the black (internal) or grey (external) membrane surfaces. Consider wearing suitable gloves to prevent damage or contamination.

  1. Install the USB-C power module into the inner fixture. Ensure the cable and USB-C socket align with the exit holes and push the board firmly into place.

  1. Carefully connect the power module to the MDL-3 membrane. The red wire to the positive (+) terminal and black to the negative (-). The terminals are of different sizes to prevent incorrect polarity—do not force or reverse them.
  2. Correctly orientate the MDL-3 membrane with the lettering, terminal marking, and black face visible, as picture. Then position the membrane between the mounting pegs.

NOTE: If the lettering and terminal markings are facing down, the membrane will humidify the enclosure.

  1. Slide the inner cover into position. The small notch at the top of the inner cover should be at the same end as the power adapter board.
  2. Insert the gasket into the slot in the retaining frame with the flat side against the MDL-3 membrane.
  3. Final Mounting
  • Position the assembled unit over the enclosure cutout.
  • Use the original MDL-3 gasket between the installation kit and the enclosure wall and fix in position with the nuts and bolts provided in the M5-PKT kit.
  • If the enclosure wall is flexible, add the back plate inside the enclosure to ensure a secure and airtight seal. Orientate the backplate so that the full membrane surface is visible.

Supplied Parts List

  • MDL-3 membrane and gasket
  • MDL-3-SET 3-part mounting fixture (inner + outer covers)
  • Wired VREG2 USB-C power adapter module with 90° flat terminal connectors
  • Rectangular rubber sealing ring.
  • Fixing screw kit

 

Notes

  • Ensure correct insertion of all connections before final assembly.
  • Always use the provided sealing ring to prevent leaks.
  • Check that the gasket is compressed properly for an airtight seal.
  • Avoid any air gaps in the enclosure for optimal performance.

 