Installation Guide for MDL-Series membranes and optional retaining plates

 

MDL mounting kits (MDL-3KIT, MDL-5KIT and MDL-7KIT)

The optional Rosahl mounting kits for MDL-Series membranes simplify installation.  Fabricated from 3mm thick 304 grade pre-drilled stainless steel, three models are available, one for each size MDL membrane.

Each kit includes a retaining plate and two gaskets. The gaskets are manufactured from 2mm thick closed cell ethylene propylene (EPT) material. If gaskets are supplied locally, they should be made from similar material with a hardness of 8±5mm.

MDL Installation

As shown in the figure, fit the packing to both sides of the dehumidifying element, attach the retainer plate on the top and fasten at around four points around the edge with M4 screws. Care should be taken to ensure the membrane terminals are adequately distanced or insulated from the panel surface.

Rosahl rain cover

When installing in an outdoor panel, a rain cover and environmental protection sheet (VTS) should be used. Avoid interference the rain cover mounting screws. When selecting an optional rain cover with the MDL-3 and MDL-5 use M-5J1R rain cover. For the MDL-7, use the M-7J1R rain cover

Figure 1. Gasket dimensions (mm)

Model nameMDL-3MDL-5MDL-7
Retaining plate setMDL-3KITMDL-5KITMDL-7KIT
Dimension a457090
Dimension b707090
Dimension c305575
Dimension d555575

 

Figure 2. Retainer plate dimensions (mm)

Model nameMDL-3MDL-5MDL-7
Dimension e80105125
Dimension f757595
Dimension g305575
Dimension h555575
Dimension i7095115
Dimension j404060

Figure 3. Installation Dimensions (mm)

Model nameMDL-3MDL-5MDL-7
Dimension m 305575
Dimension n555575
Dimension p7095115
Dimension q404060

 

Westside-International Ltd

Boston House, Downsview Road, Wantage, Oxfordshire, OX12 9FF. UK